PEX-A Branch Supply Linear Footage
Worked Example: 320 ft measured × 1.15 = 368 ft → Order 400 ft PEX coils
For licensed plumbers and mechanical contractors
Separate PEX/copper materials, fixture allowances, permit fees, and labor hours cleanly. Homeowners see what is included — zero invoice surprises.
Free to use - No signup - PDF + PNG
What you send
Proposal
Your Business
#4821
Prepared for Hannah Reyes
Project 50-gal tank water heater & main PRV valve replacement
Pre-filled — just change names and prices.
Verify shut-off integrity, static water pressure, venting code compliance, and wall access before issuing a fixed plumbing proposal.
Test static street water pressure (45–80 PSI target) and confirm whether the existing main gate/ball shut-off actually seals before cutting supply pipes.
Document galvanized steel, polybutylene, cast-iron DWV, or Type M copper transitions requiring dielectric unions or full replacement.
Verify Category I/IV exhaust venting clearance, T&P relief termination line, sediment trap, and code-required thermal expansion tank sizing.
Locate 3"/4" exterior cleanouts and confirm whether hydro-jetting or camera scoping is required prior to tying new rough-ins into old clay/cast mains.
Mark exact drywall, plaster, or slab concrete saw-cut zones needed for repiping and confirm finish restoration remains excluded unless quoted separately.
Confirm city permit fees and inspector pressure-test scheduling windows before quoting mobilization dates.
Fixture unit math, PEX/copper pipe waste buffers, and licensed plumbing production rates.
Worked Example: 320 ft measured × 1.15 = 368 ft → Order 400 ft PEX coils
Worked Example: 50-gal water heater at 65 PSI → Minimum 2.0-gallon pre-charged expansion tank
| Trade Task / Scope | Standard Labor Output | Material Coverage / Waste | Prep & Complexity Factor |
|---|---|---|---|
| 50-Gal Gas/Electric Water Heater Swap (Same Location) | 3.5 – 5.0 crew hrs | 1 unit + pan/PRV/valve kit | +1.5 hrs if vent flue or gas trap modification needed |
| Whole-Home PEX-A Repipe (2-Bath House) | 20 – 28 crew hrs | +15% piping & manifold fittings | +30% for crawlspace < 24 in. clearance or slab routing |
| 3-Piece Bathroom Rough-In (PVC DWV + PEX) | 12 – 18 crew hrs | +10% pipe & hub fitting waste | +40% if cutting and patching slab concrete |
| Main Sewer Hydro-Jet & Camera Locate | 2.0 – 3.5 hrs / visit | Flat equipment mobilization | +1.5 hrs if roof vent access required (no exterior cleanout) |
Replace vague plumbing line items that trigger surprise charges or unpaid rework with clear, measurable scope language.
| Dispute Trigger / Scope Area | Ambiguous Quote Wording (Avoid) | Why It Causes Disputes | Transparent Quote Alternative (Use This) |
|---|---|---|---|
| Water Heater Code Upgrades | Replace water heater and haul away old unit — $1,650 | Leaves expansion tanks, drain pans, sediment traps, and shut-off valves out, causing inspection failures or surprise day-of upsells. | Install 50-gal commercial-grade water heater, 2.0-gal pre-charged thermal expansion tank, galvanized drain pan, quarter-turn brass ball valve, gas sediment trap, and haul away old unit. |
| Drywall Patching After Repiping | Whole-house PEX repipe included | Homeowners expect repiped rooms to be mudded and repainted ready for guests, while plumbers priced only piping and testing. | PEX-A supply repipe with pressure test at 80 PSI and flush included. Access cuts in drywall/plaster are minimized and left broom-clean; finish drywall patching, texture, and painting excluded. |
| Concealed Cast-Iron Drain Rot | Bathroom plumbing rough-in fixed price | Attaching new PVC traps to corroded 1960s galvanized/cast branches leads to mid-job arguments over unbudgeted stack replacement. | Connect new 3-piece PVC rough-in to existing sound branch stack. If wall opening exposes rusted or split cast-iron stack, repair section quoted via written change order with photos before closing wall. |
Copy these transparent, plain-English clauses directly into your plumbing proposal terms to protect both contractor and client from unforeseen defects, supply shifts, and warranty disputes.
CONCEALED PIPE & SLAB PROTOCOL: Opening walls, ceilings, or slab concrete may expose pre-existing corroded drain stacks, rotted subfloors, or buried obstructions not visible at walkthrough. Work in that zone will pause immediately so we can share photo proof and submit a written change order for approval before proceeding.
DRYWALL & TILE ACCESS BOUNDARY: Unless finish restoration is explicitly itemized on this proposal, our crew minimizes wall/ceiling access cuts to complete plumbing repairs safely and leaves rough openings clean; finish drywall mudding, texture, painting, and tile replacement remain excluded.
WORKMANSHIP & MANUFACTURER WARRANTY: We warrant our solder/press/PEX joints, drain slope, and installation labor for 24 months. Equipment tanks, valves, and owner-supplied fixtures remain covered solely under the manufacturer's factory warranty; sewer root regrowth is excluded from drainage warranty.
How it works
Select plumbing scope
Pick a repipe, water heater swap, or rough-in preset and adjust quantities.
Verify permit and tax rules
Add shut-off valves, expansion tanks, and regional tax or deposit settings.
Export PDF or PNG
Send formal PDF by email or PNG by SMS straight from the jobsite.
Trade Guide
Clear plumbing estimates protect both homeowner and contractor by separating pipe material specifications (such as Type L copper vs. Uponor PEX-A), fixture model numbers, and licensed installation labor. When a quote lumps 'install new water heater and valves' into one vague figure, clients cannot compare tank warranty tiers or verify code upgrades like sediment traps, pan drains, and thermal expansion tanks.
Always specify access and restoration boundaries in writing. State whether access holes cut into drywall, plaster, or slab concrete remain the client's responsibility to patch via a finish contractor, note whether municipal permit and backflow testing fees are billed at direct pass-through cost, and define a clear deposit schedule (typically 30%–40% for water heater or repipe materials) before mobilization.
Use these typical cost baselines to price your plumbing bids competitively and transparently.
| Service / Scope | Typical Range | Billing Model | Scope Details |
|---|---|---|---|
| 50-Gallon Gas/Electric Water Heater Swap | $1,450 - $2,600 | Flat equipment + labor install | Includes pan, shut-off valve, expansion tank & haul-away of old unit. |
| Whole-Home PEX-A Repipe (2-Bath) | $4,800 - $8,500 | By fixture count / home size | Includes hot/cold manifolds & pressure test; finish drywall excluded. |
| Sewer Line Hydro-Jetting & Camera Scope | $350 - $750 | Flat diagnostic + per-visit jet | Includes recorded HD camera video inspection to locate root intrusion. |
| Bathroom Rough-In (3-Piece Drain/Supply) | $2,200 - $3,900 | Per fixture opening | PVC DWV piping, PEX water lines, and air/water inspection test. |
Yes — list the water heater, thermal expansion tank, and shut-off valve on dedicated material rows apart from installation labor.
Include a concealed condition clause explaining that rotted drain stacks or corroded framing discovered after wall opening are quoted via written change order.
You can toggle permits under Inclusions/Exclusions or add an explicit pass-through fee row billed at exact city receipt cost.
Most plumbing proposals exclude finish drywall, texture matching, and tile restoration unless explicitly added; listing that exclusion prevents post-job disputes.
No. Everything runs locally in your browser with zero login or cloud database.
Open the free editor — no signup. Download PDF for email or PNG for texting.
Create proposal nowContinue your plumbing quoting workflow with companion field protocols, estimation guides, and adjacent trade generators.
Separate water heaters, brass valves, permit fees, and finish drywall exclusions.
Document concealed stack rot behind closed walls before performing extra repairs.
Test static PSI, main shut-off valves, and sewer cleanouts prior to bidding.
Coordinate bathroom rough-ins cleanly with tile, vanity, and waterproofing scopes.